The NEW proCHEM Series controllers provide an economical answer to most process monitoring, control or recording requirements.
Dual Set Points are provided. The default setup for these are as "Too High" and "Too Low" control points. The user can also re-set them so that they are both "Too High" or both "Too Low" control points. An example of this type of setup is where the proCHEM unit has one point set to control the process, and a second point beyond that set to activate an alarm.
Dual Set Points are provided. The default setup for these are as "Too High" and "Too Low" control points. The user can also re-set them so that they are both "Too High" or both "Too Low" control points. An example of this type of setup is where the proCHEM unit has one point set to control the process, and a second point beyond that set to activate an alarm.
Separate LED's indicate when either of the Set Points has been exceeded. The output relays are rated to 240V and are fused at 1 Amps. Higher currents can be switched with an external contactor. All proCHEM units are easy to install. They are housed in a rugged plastic case which is non corrosive, waterproof and dustproof to IP65. All controls can be accessed via the hinged, clear cover. The large LCD display is easy to read, even from a distance.
The proCHEM series is designed for maximum flexibility. 4 to 20 mA and 0 to 1 V DC outputs are provided as standard.
For a total solution to your control requirements, TPS also offers a peristaltic pump, the easyFLOW-VS.
The proCHEM series is proudly designed and manufactured in Australia. The TPS Quality System has been certified in accordance with AS/NZS ISO9001 standards. Since 1968, TPS has built a reputation for excellent backup service that is second to none.
Product Group | No |
---|---|
Technical Information | Ranges
0 to 199.9 % Saturation OR 0 to 19.99 ppM (mg/L) (Factory-set) Resolution
0.1 % Saturation OR 0.01 ppM (mg/L) Accuracy
+/-0.2% of full scale Linearity
+/-0.1% Repeatability
+/-0.2% Ambient Drift
<0.05% span/OC Long Term Drift
<0.2% per year Temperature Compensation
Dual automatic temperature compensation system,(sensor limit 45 OC). Zero Range
+/-10% Span Range
70 to 130% Sensor
YSI5739 Polarographic sensor with inbuilt ATC sensor. Enclosure
Polycarbonate, waterproof to IP65 Display
12.5mm LCD Outputs
4 to 20 mA (500 Ohms max load) 0 to 1 V DC (0 to 10 V DC optional) Contacts : One optional relay with changeover contacts. Rated to 240V, 1 Amp Isolation
Galvanic isolation of sensor input Current and voltage outputs are not isolated Power
220/240 V AC, 50/60Hz (110/120 V AC available) 12V DC power optional. Dimensions
172 x 160 x 71mm Mass
Instrument only : Approx 800g Full Kit : Approx 1.5kg Instrument Operating Environment Temperature : 0 to 45 OC Humidity : 0 to 95% R.H. |
Pack size | EACH |
Ranges
0 to 199.9 % Saturation
OR 0 to 19.99 ppM (mg/L) (Factory-set)
0 to 199.9 % Saturation
OR 0 to 19.99 ppM (mg/L) (Factory-set)
Resolution
0.1 % Saturation
OR 0.01 ppM (mg/L)
0.1 % Saturation
OR 0.01 ppM (mg/L)
Accuracy
+/-0.2% of full scale
+/-0.2% of full scale
Linearity
+/-0.1%
+/-0.1%
Repeatability
+/-0.2%
+/-0.2%
Ambient Drift
<0.05% span/OC
<0.05% span/OC
Long Term Drift
<0.2% per year
<0.2% per year
Temperature Compensation
Dual automatic temperature
compensation system,(sensor limit 45 OC).
Dual automatic temperature
compensation system,(sensor limit 45 OC).
Zero Range
+/-10%
+/-10%
Span Range
70 to 130%
70 to 130%
Sensor
YSI5739 Polarographic sensor with inbuilt ATC sensor.
YSI5739 Polarographic sensor with inbuilt ATC sensor.
Enclosure
Polycarbonate, waterproof to IP65
Polycarbonate, waterproof to IP65
Display
12.5mm LCD
12.5mm LCD
Outputs
4 to 20 mA (500 Ohms max load)
0 to 1 V DC (0 to 10 V DC optional)
Contacts : One optional relay with changeover contacts. Rated to 240V, 1 Amp
4 to 20 mA (500 Ohms max load)
0 to 1 V DC (0 to 10 V DC optional)
Contacts : One optional relay with changeover contacts. Rated to 240V, 1 Amp
Isolation
Galvanic isolation of sensor input
Current and voltage outputs are not isolated
Galvanic isolation of sensor input
Current and voltage outputs are not isolated
Power
220/240 V AC, 50/60Hz
(110/120 V AC available)
12V DC power optional.
220/240 V AC, 50/60Hz
(110/120 V AC available)
12V DC power optional.
Dimensions
172 x 160 x 71mm
172 x 160 x 71mm
Mass
Instrument only : Approx 800g
Full Kit : Approx 1.5kg
Instrument only : Approx 800g
Full Kit : Approx 1.5kg
Instrument Operating Environment
Temperature : 0 to 45 OC
Humidity : 0 to 95% R.H.
Temperature : 0 to 45 OC