Product Categories
- Apparatus
- Chemicals
-
Equipment
- Autoclaves
- Balances
- Centrifuges
- Colony Counters
- Dispersers
- Dry Block Heaters
- Environmental Chambers
- Filtration
- Freezers
- Fume Cupboards
- Furnaces
- Grinders & Mills
- Specials
- Second Hand
HI 93703 series are microprocessor based turbidity meters that provide laboratory accuracy for field turbidity measurements.
The HI 93703 is easy to calibrate (with 3 point calibration) using AMCO-EPA standards and is ISO 7027 compliant.
HANNA instruments has chosen 10 FTU* as the calibration point because it is the value that best fits the water turbidity measurements in different applications, from drinking water to wastewater treatment. HANNA instruments uses the primary standard AMCO-AEPA-1 to avoid all formazine-related problems. Formazine is a very toxic, unstable substance which requires particular care: its standards have to be prepared only a few minutes before performing the calibration, and cannot be reused because of their short life. HANNA AMCO-AEPA-1 standards are extremely stable, can be reused, and last up to six months if free from contamination. HI 93703 can be used with both standards.
Both versions meet the requirements of GLP (Good Laboratory Practice) protocols for last calibration data storage.
GLP Features
- 3 point calibration
- Logging for up to 199 measurements (HI 93703-11)
- PC Connectivity (HI 93703-11)
HI 93703 is supplied complete with glass cuvette, batteries and instructions.
Product Group | No | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Technical Information |
|
||||||||||||||||||||
Pack size | EACH |
Range | 0.00 to 50.00 FTU; 50 to 1000 FTU |
Resolution | 0.01 FTU (0.00 to 50.00 FTU); 1 FTU (50 to 1000 FTU) |
Accuracy | ±0.5 FTU or ±5% of reading (whichever is greater) |
Calibration | 3 points (0 FTU, 10 FTU and 500 FTU) |
Light Source | infrared LED |
Light Detection | Silicon Photocell |
Battery Type / Life | 1.5V AA (4) /approximately 60 hours of continuous use or 900 measurements; auto-off after 5 minutes of non-use |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Dimensions | 220 x 82 x 66 mm (8.7 x 3.2 x 2.6") |
Weight | 510 g (1.1 lb.) |